Ferroli Domina C 24 E Manual

Ferroli Domina C 24 E Manual

Ferroli Domina C 24 E Manual Rating: 8,9/10 7256 votes

14 section 5 - installation Instructions 5.1 Boiler Packaging The boilers are supplied in different packagings: Boiler Flue System (separate) Hardware Pack (separate) 5.2 Fitting/Mounting the Boiler Decide where the boiler is to be fixed on the wall, taking into account installation requirements detailed in previous section. Screw the wall mounting plate to the wall choosing one of the two sets of slots in left and right bank. Ensuring that at least one of the screws is fitted into a top slot. Example of fixing 5.4 internal wiring The boiler has been pre-fitted with a 3 amp fused approved moulded 3 pin and flying lead for use with 230V 50Hz. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. The plug should be used with an unswitched/shuttered socket outlet complying with BS1363.

Ferroli Limited Lichfield Road Branston Industrial Estate Burton-upon-Trent Staffordshire DE14 3HD United Kingdom T: 0330 205 0002 Registered in England 03335187 Calls to our 0330 numbers cost the same as a call to an 01 or 02 national number whether from a landline or mobile. 1 GB24 & GB30 User & Installation Instructions off max e status burner mode reset. DHW/Preheat Control Knob C. CH Control Knob D. Boiler Status E. FERROLI F30 INSTALLATION, SERVICING AND USER INSTRUCTIONS. Mediafire highly compressed games. DOMINA 102 COPPER WALL-MOUNTED COMBINATION, GAS FIRED.

Listed below are the AWS architecture diagram examples in this post; • • • • • • • • • • AWS VPC architecture diagram with Public and Private Subnets This template represents a scenario that includes a VPC or a virtual private cloud with a public subnet and a private subnet. Diagram Simply click the template that meets your requirements to modify it online.

The boiler comes pre-fitted with a link wire between the room thermostat/timer connections on the terminal strip. This creates a permanent call for heat and must be removed when adding a room thermostat. 4 Cable Clamp 2.

Pdf

Lift the boiler onto the wall mounting plate, locating it over the two tabs. Room Thermostat - Wiring To fit a room thermostat proceed as follows: 1. Ensure that the electrical supply to the boiler is isolated before proceeding. Remove the two screws beneath the flap on the front of the boiler and lower the front panel. Remove the pre-fitted link wire between the Room stat/timer terminals. Pass the cable through a grommet, secure with the cable clamp and connect the room stat as shown in the diagram below.

Ferroli Domina C 24 E Manual

If room stat has a neutral connection, connect this to terminal N (load) in the fused spur. Carry out all necessary electrical checks. Raise the front panel and relocate the two screws under the small flap. Check operation of room stat if possible. If present, remove the bottom end support packaging and ensure all plastic plugs are removed from CH & DHW connections. 5.3 Wiring InstruCTIons WARNING: THIS APPLIANCE MUST BE EARTHED Connections must be made in such a way that allows complete isolation of the electrical supply, e.g. Double pole switch with 3mm contact separating in both poles.

Ferroli Domina C 24 E Manual
© 2019